Insulation Resistance Meters :

MIC-15k1 :

MIC-15k1 meter is designed to measure insulation resistance of power objects such as single- and multicore cables, transformers, motors and generators, capacitors, switches and other devices installed in power stations.

It is especially recommended for measurements in areas with very high electromagnetic disturbances, e.g. electrical substations with 1200 kV AC and 500 kV DC. Thanks to the 15 kV measuring voltage (in accordance with ANSI / NETA ATS-2009 TABLES 100.1) the meter can be used for measuring objects with a nominal voltage above 34.5 kV,…

MIC-10k1 :

Insulation resistance measurement:up to 40 TΩ, measurement voltage any in the range of: 50…10000 V (50…1000 V at 10 V and 1…10 kV at 25 V), continuous indication of measured insulation resistance or leakage current, automatic discharge of measured object capacitance voltage after the end of insulation resistance measurement, acoustic signaling of 5 seconds intervals to facilitate capturing time characteristics, adjustable measuring time to 99’59’’, metered T1, T2 and T3 test times for measuring one or two absorption coefficients from the range of 1…600 s, polarization index (PI), absorption coefficients Ab1, Ab2 and dielectric absorption ratio (DAR) measurement, indication of actual test voltage during measurement,1.2 mA, 3 mA and 6 mA test current, insulation resistance measurement using two- or three-wire method,….

 

MIC-5050 :

Insulation resistance measurement up to 20 TΩ, measurement voltage any in the range of: 50…5000 V (50…1000 V at 10 V and 1…5 kV at 25 V), continuous indication of measured insulation resistance or leakage current, automatic discharge of measured object capacitance voltage after the end of insulation resistance measurement, acoustic signaling of 5 seconds intervals to facilitate capturing time characteristics, adjustable measuring time to 99’59’’, metered T1, T2 and T3 test times for measuring one or two absorption coefficients from the range of 1…600 s, polarization index (PI), absorption coefficients Ab1, Ab2 and dielectric absorption ratio (DAR) measurement, indication of actual test voltage during measurement, 1.2 mA, 3 mA and 6 mA+/-15% test current, insulation resistance measurement using two- or three-wire method,….

 

MIC-5010 :

Measurement voltage any in the range of 50…1000 V at 10 V and 1000…5000 V at 25 V resolution, continuous indication of measured insulation resistance or leakage current, automatic discharge of measured object capacitive voltage after the end of insulation resistance measurement, 1.2 mA and 3 mA test current, step voltage insulation resistance measurement (SV), Dielectric Discharge calculation (DD), protection against measuring live objects, DC and AC voltage measurement in the range of 0…600 V, 990 cells of memory (11880 records) with the capability of wireless data transmission to a PC  or through a USB cable,…

 

MIC-5005 :

Measurement voltage any in the range of 50…1000 V at 10 V and 1000…5000 V at 25 V resolution, continuous indication of measured insulation resistance or leakage current,automatic discharge of measured object capacitive voltage after the end of insulation resistance measurement, acoustic signaling of 5 seconds intervals to facilitate capturing time characteristics, metered T1 , T2 and T3 test times for measuring one or two absorption coefficients from the range of 1…600 s, adjustable measuring time to 99’59’’,…

 

MIC-5001 :

Insulation resistance measurement in a compact up to 5 TΩ, light-weight, low-cost design, measuring voltage selectable from 50 V to 500 V range in 50 V steps, and from 500 V to 5000 V range in 100 V steps, continuous indication of insulation resistance or leakage current, automatic discharge of stored charge due to capacitance of tested object after the insulation resistance measurement, measurement of alternating and direct voltages from 0 V to 750 V , 990 cells of memory (11880 records) to record results, data transfer to PC via USB cable, built-in rechargeable battery pack, meets the requirements of the EN 61557 standard,…

 

MIC-2501 :

Selectable measurement voltage in the 100…2500 V range with 100 V step, continuous indication of insulation resistance or leakage current, automatic discharge of capacitance of tested object after the insulation resistance measurement, continuity measurement of protective and equipotential conductors according to EN 61557-4 , with the >200 mA current,…

 

MIC-30 :

The MIC-30 is a hand-held, rugged, easy-to-use, 1 kV class insulation test meter, insulation resistance measurement to 100 GΩ, user selected test voltages: 50, 100, 250, 500, 1000 V in 10 V steps, displays continuous indication of insulation resistance or leakage current, audio beeps every five-second periods to indicate measurement progress, indication of actual test voltage during the measurement, 4 AA disposable or rechargeable batteries, continuous indication of state of battery charge,…

 

MIC-10 :

Selected test voltage: 50, 100, 250, 500, 1000 V, continuous indication of insulation resistance or leakage current, automatic discharge of capacitance of tested object after the insulation resistance measurement, continuity measurement of protective and equipotential conductors according to EN 61557 – 4 with the >200 mA current, low-voltage circuit continuity and resistance measurement, masurement of alternating and direct voltages in the 0…600 V range, power supply: 4 AA disposable or rechargeable batteries, monitoring of power supply voltage, meter conform to EN 61557,…

 