High Voltage Equipment :

S-25 DC :

MV and HV insulation under full control

The S-25DC device is a universal high voltage tester. It stands out in a special way. Not only by its modest dimensions. Due to its internal rechargeable battery, it allows tests even when mains power is unavailable.  

Capacitive objects, such as shielded power cables, will be correctly and automatically discharged by the integrated discharge module if an error occurs or the test time expires. A key switch, a switch-on lock and a protective earthing circuit ensure maximum safety.  

S-50 DC :

MV and HV insulation under full control

The S-50DC device is a universal high voltage tester. It is extremely durable, but also lightweight, compact and easy to carry due to its transport case on wheels.

Capacitive objects, such as shielded power cables, will be correctly and automatically discharged by the integrated discharge module if an error occurs or the test time expires. A key switch, a switch-on lock and a protective earthing circuit ensure maximum safety.

S-80 DC :

MV and HV insulation under full control

The S-80DC device is a universal high voltage tester. It is extremely durable, but also lightweight, compact and easy to carry due to its transport case on wheels.

Capacitive objects, such as shielded power cables, will be correctly and automatically discharged by the integrated discharge module if an error occurs or the test time expires. A key switch, a switch-on lock and a protective earthing circuit ensure maximum safety.

S-110 DC :

MV and HV insulation under full control

The S-110DC device is a universal high voltage tester. It is extremely durable, but also lightweight, compact and easy to carry due to its transport case on wheels.

Capacitive objects, such as shielded power cables, will be correctly and automatically discharged by the integrated discharge module if an error occurs or the test time expires. A key switch, a switch-on lock and a protective earthing circuit ensure maximum safety.

S-120 DC :

MV and HV insulation under full control

The S-120DC device is a universal high voltage tester. It is extremely durable, but also lightweight, compact and easy to carry due to its transport case on wheels.

Capacitive objects, such as shielded power cables, will be correctly and automatically discharged by the integrated discharge module if an error occurs or the test time expires. A key switch, a switch-on lock and a protective earthing circuit ensure maximum safety.

S-24 VLF :

Test the condition of the cables with VLF or DC slow voltage  

The S-24 VLF high voltage insulation tester is a compact, robust and portable kit for testing medium voltage cables according to IEEE400, IEC 60502-2, CENELEC HD 620 and 621 and DIN VDE 0276/620 and 621. The test is carried out using the low electrical stress method, with a VLF (Very Low Frequency) voltage of 0.1 Hz.  

The VLF test is the fastest way to detect insulation damage. The S-24 VLF instrument can test cables with plastic insulation (XLPE, PE-, EPR) as well as paper and oil insulation (PILC). Testing with DC voltage is also possible. 

S-36 VLF :

Test the condition of the cables with VLF or DC slow voltage

The S-36VLF high voltage insulation tester is a compact, robust and portable kit for testing medium voltage cables according to IEEE400, IEC 60502-2, CENELEC HD 620 and 621 and DIN VDE 0276/620 and 621. The test is carried out using the low electrical stress method, with a VLF (Very Low Frequency) voltage of 0.1 Hz. The VLF test is the fastest way to detect insulation damage.

The S-36VLF instrument can test cables with plastic insulation (XLPE, PE-, EPR) as well as paper and oil insulation (PILC). Testing with DC voltage is also possible.

S-44 VLF :

Test the condition of the cables with VLF or DC slow voltage

The S-44VLF high voltage insulation tester is a compact, robust and portable kit for testing medium voltage cables according to IEEE400, IEC 60502-2, CENELEC HD 620 and 621 and DIN VDE 0276/620 and 621. The test is carried out using the low electrical stress method, with a VLF (Very Low Frequency) voltage of 0.1 Hz.

The VLF test is the fastest way to detect insulation damage. The S-44VLF instrument can test cables with plastic insulation (XLPE, PE-, EPR) as well as paper and oil insulation (PILC). Testing with DC voltage is also possible.

S-44 VLF (110 V) :

Test the condition of the cables with VLF or DC slow voltage, Evaluate the condition of cables using VLF or DC voltage

S-57 VLF :

Test the condition of the cables with VLF or DC slow voltage

The S-57VLF high voltage insulation tester is a compact, robust and portable kit for testing medium voltage cables according to IEEE400, IEC 60502-2, CENELEC HD 620 and 621 and DIN VDE 0276/620 and 621. The test is carried out using the low electrical stress method, with a VLF (Very Low Frequency) voltage of 0.1 Hz.

The VLF test is the fastest way to detect insulation damage. The S-57VLF instrument can test cables with plastic insulation (XLPE, PE-, EPR) as well as paper and oil insulation (PILC). Testing with DC voltage is also possible.