Select Page

submersible probes | level probes

BD|SENSORS offers a wide range of submersible probes designed for the measurement of fill levels of fluid or paste-like media or for levels of water and waste-water. The sensors are based on hydrostatic pressure, i.e. the fill level is found by measuring pressure.

The submersible probes are available with many types of enclosure materials, pressure sensors and diameters and will thus in their standard version already offer perfect solutions to predominant installation conditions. 
The detachable submersible probes are noteworthy. These designs allow very simple detachment of probe and cable, requiring no tools. This is a decisive advantage during maintenance or servicing, since only part of the submersible probe will require attention, not the entire installation.

  • with stainless steel sensor LMP 308i | LMP 308
  • with ceramics sensor LMK 358H | LMK 358 | LMK 808

The range also includes other designs such as submersible probes with integrated overvoltage protection, temperature sensors or data loggers, also types communicating via RS 485 interface or HART® protocol.

MATRIX LEVEL PROBES

DCL 531i

stainless steel sensor
with RS485 Modbus RTU Ø 26.5

nominal pressure:0 ... 1 mH2O up to 0 ... 250 mH2O

accuracy:0.1 % FSO

CEModbus RTUDVGW hygienic

LMP 307i

stainless steel sensor
stainless-steel probe Ø 26.5

nominal pressure:0 ... 4 mH2O up to 0 ... 200 mH2O

accuracy:0.1 % FSO

CEExIECEXDVGW hygienicUL

LMP 308i

stainless steel sensor
detachable stainless steel probe Ø 35

nominal pressure:0 ...4 mH2O up to 0...200 mH2O

accuracy:0.1 % FSO

CEULExIECEX

LMK 358 H

ceramic sensor
detachable stainless steel probe Ø 39.5

nominal pressure range0 ... 60 cmH2O up to 0 ... 100 mH2O

accuracy:0.1 %

CEExHARTUL

LMK 382 H

ceramic sensor
steel probe Ø 39.5

nominal pressure range0 ... 60 cmH2O up to 0 ... 200 mH2O

accuracy:0.1 % FSO

CEExHARTUL

LMK 387 H

ceramic sensor
with HART®-communication

nominal pressure:von 0 ... 1 mH2O bis 0 ... 100 mH2O

accuracy:0.35 % (opt. 0.25 %) FSO

CEExIECEXDVGW hygienicHART

DCL 531

stainless steel sensor
with RS485 Modbus RTU

nominal pressure:0 ... 1 mH2O up to 0 ... 250 mH2O

accuracy:0.25 % FSO

CEDVGW hygienicModbus RTUUL

DCL 532

stainless steel sensor
with I2C

nominal pressure:from 0 ... 1 mH2O up to 0 ... 40 mH2O

accuracy:0.25 % (Opt. 0.1 %) FSO

I2C

DCL 571

ceramic sensor
with RS485 Modbus RTU

nominal pressure:0 ... 1 mH2O up to 0 ... 100 mH2O

accuracy:0.35% (opt. 0.35 %) FSO

CEDVGW hygienicModbus RTUUL

LMK 458

ceramic sensor
stainless steel probe Ø 39,5

nominal pressure:0 ... 40 cmH2O up to 0 ... 200 mH2O

accuracy:0.35 % (opt. 0.1 %) FSO

CEULExABSBVCCSDNV-GLLloyd´s Register

LMK 458 H

ceramic sensor
hydrostatic HART-probe Ø 39,5

nominal pressure:0 ... 60 cmH2O up to 0 ... 200 mH2O

accuracy:0.1 % FSO

CEULExABSBVCCSDNV-GLLloyd´s RegisterHART

LMK 487

ceramic sensor
probe Ø 22mm

nominal pressure:0 ... 1 mH2O up to 0 ... 100 mH2O

accuracy:0.25 % FSO

CEULExDNV-GLLloyd´s Register

LMP 305

stainless steel sensor
slimline-probe Ø 19

nominal pressure:0 ... 1 mH2O up to 0 ... 250 mH2O

accuracy:0.35 % (opt. 0.25 %) FSO

CEUL

LMP 307

stainless steel sensor
stainless steel probe Ø 27

nominal pressure:0 ... 1 mH2O up to 0 ... 250 mH2O

accuracy:0.35 % (opt. 0.25% / 0.1 %) FSO

CEExIECEXDVGW hygienicSILUL

LMP 307T

stainless steel sensor
stainless steel probe Ø 27

nominal pressure:0 ... 1 mH2O up to 0 ... 250 mH2O

accuracy:0.35 % (opt. 0.25 %) FSO

CEULDVGW hygienic

LMP 308

stainless steel sensor
detachable stainless steel probe Ø 35

nominal pressure:0 ... 1 mH2O up to 0 ... 250 mH2O

accuracy:0.35 % (opt. 0.25% / 0.1 %) FSO

CEExIECEXSILUL

LMK 306

ceramic sensor
stainless steel probe Ø 17

nominal pressure:0 ... 6 mH2O up to 0 ... 200 mH2O

accuracy:0.5 % FSO

CEUL

LMK 307

ceramic sensor
stainless steel probe Ø 27

nominal pressure:0 ... 4 mH2O bis 0 ... 250 mH2O

accuracy:0,5 % FSO

CEExIECEXSILUL

LMK 307 T

ceramic sensor (flush)
level and temperature transmitter Ø 26,5

nominal pressure:from 0 ... 4 mH2O up to 0 ... 250 mH2O

accuracy:0,5 % FSO

CEUL

LMK 358

ceramic sensor
detachable stainless steel probe Ø 39,5

nominal pressure:0 ... 40 cmH2O up to 0 ... 100 mH2O

accuracy:0.35 % (opt. 0.25 %) FSO

CEExUL

LMK 382

ceramic sensor
stainless steel probe Ø 39,5

nominal pressure:0 ... 40 cmH2O up to 0 ... 200 mH2O

accuracy:0.35 % (opt. 0.25 %) FSO

CEExUL

LMK 387

ceramic sensor (flush)
Stainless Steel Probe 22 mm

nominal pressure:from 0 ... 1 mH2O up to 0 ... 100 mH2O

accuracy:0.35 % (opt. 0.25 %) FSO

CEExIECEXDVGW hygienicUL

level probe LMK806

LMK 806

ceramic sensor (flush)
Plastic Probe Ø 21

nominal pressure:from 0 ... 6 mH2O up to 0 ... 100 mH2O

accuracy:0,5% FSO

CEUL

level probe LMK807

LMK 807

ceramic sensor
plastic submersible probe Ø 35

nominal pressure:0 ... 4 mH2O up to 0 ... 100 mH2O

accuracy:0.5 % FSO

CESILUL

level probe LMK808

LMK 808

ceramic sensor
detachable plastic level probe Ø 35

nominal pressure:0 ... 1 mH2O up to 0 ... 100 mH2O

accuracy:0.35 % (opt. 0.25 %) FSO

CEUL

level probe LMK809

LMK 809

ceramic sensor
plastic probe Ø 45

nominal pressure:0 ... 40 cmH2O up to 0 ... 100 mH2O

accuracy:0.35 % (opt. 0.25 %) FSO

CEUL

Product catalogue hydrostatic probes and screw-in transmitters

Please visit our up to date product catalog for information on our range of pressure transmitters. Please download the pdf file here, fast, easy and at no charge.

download product catalogue