Piezoelectric Pressure Sensor:

pressure ranges 0 … 8000 bar
highly dynamic pressure recording up to 50 kHz

The new DAC series allows accurate recording of measured values in extreme situations, such as pressure spikes or pressure surges, pressure gradients during explosions or combustions, e.g. in the case of ballistic measurements or the ignition of internal combustion engines.

Piezoelectric sensors are suitable for dynamic measurements up to ranges of more than 100 kHz. They are very small and can easily be integrated into the applications. Use of the DAC requires a charge amplifier which converts the generated electric charge into a corresponding output signal.

DAC 102

dynamic pressure measurements
for precision measurement

nominal pressure range0 … 250 bar

operating temperature °C-40 … 400

sensitivity pC/bar35

natural frequency kHz85

DAC 103

dynamic pressure measurements
for heavily vibrating systems

nominal pressure range0 … 250 bar

operating temperature °C-40 … 400

sensitivity pC/bar16

natural frequency kHz165

DAC 105

dynamic pressure measurements for high
pressure at moderate temperatures

nominal pressure range0 … 500 bar

operating temperature °C-50 … 120

sensitivity pC/bar19

natural frequency kHz170

DAC 105G

dynamic pressure measurements
all-round sensor

nominal pressure range0 … 250 bar

operating temperature °C-40 … 400

sensitivity pC/bar19

natural frequency kHz160

DAC 105K

dynamic pressure measurements
all-round sensor

nominal pressure range0 … 300 bar

operating temperature °C-40 … 400

sensitivity pC/bar19

natural frequency kHz170

DAC 106G

dynamic pressure measurements
all-round sensor

nominal pressure range0 … 250 bar

operating temperature °C-40 … 400

sensitivity pC/bar19

natural frequency kHz160

DAC 106K

dynamic pressure measurements
all-round sensor

nominal pressure range0 … 300 bar

operating temperature °C-40 … 400

sensitivity pC/bar19

natural frequency kHz170

DAC 106L

dynamic pressure measurements
for high pressures at high temperatures

nominal pressure range0 … 500 bar

operating temperature °C-40 … 400

sensitivity pC/bar10

natural frequency kHzapprox. 170

DAC 106U

dynamic pressure measurements
Extremely rapid, for high pressures

nominal pressure range0 … 650 bar

operating temperature °C-40 … 350

natural frequency kHz> 400

sensitivity pC/barapprox. 1.5

DAC 107

dynamic pressure measurements
for precision measurement

nominal pressure range0 … 250 bar

operating temperature °C-40 … 400

sensitivity pC/bar45

natural frequency kHzapprox. 92

DAC 109

dynamic pressure measurements
highly robust, continual use

nominal pressure range0 … 250 bar

operating temperature °C-40 … 350

sensitivity pC/bar20

natural frequency kHzapprox. 90

DAC 120

dynamic pressure measurements
for extreme pressure peaks

nominal pressure range0 … 2000 bar

operating temperature °C-50 … 200

sensitivity pC/bar5.2

natural frequency kHz> 240

DAC 160

dynamic pressure measurements
for extreme pressure peaks

nominal pressure range0 … 6000 bar

operating temperature °C-50 … 200

sensitivity pC/bar3

natural frequency kHz> 240

DAC 180

dynamic pressure measurements
for extreme pressure peaks

nominal pressure range0 … 8000 bar

operating temperature °C-50 … 200

sensitivity pC/bar2.3

natural frequency kHz> 240

LV 3

Digital charge amplifier for piezoelectric sensors

CE

Product brochure ‘piezoelectric pressure sensors’

Please visit our up to date product catalog for information on our range of pressure transducers. Please download the pdf file here, fast, easy and at no charge.

 

Whatsapp